Menu
  • Home
  • Products
    • Automatic Systems
    • Manual Systems
    • Multi-Detector Systems
    • Software
    • Accessories
    • Detectors
    • Instrument Comparison Chart
  • Company
    • About Us
    • Ludlum Family
    • Directions
    • Exhibition Schedule
    • Training
    • Employment Opportunities
    • Ethics Policies
  • Documents
    • Data Sheets
    • End User Statement Form
    • Technical Articles
    • Warranty
    • Radioactive Material License
    • Terms & Conditions
  • Contact
    • Headquarters
    • Sales Contact Form
    • Support Contact Form
    • Feedback Form
Protean Logo web
A Division Of Ludlum Measurements, Inc.
LMI Logo Web
(888) 707-1795 (US, CA)
(865) 392-4600
(865) 392-4600
  • Home
  • Products
    • Automatic Systems
    • Manual Systems
    • Multi-Detector Systems
    • Software
    • Accessories
    • Detectors
    • Instrument Comparison Chart
  • Company
    • About Us
    • Ludlum Family
    • Directions
    • Exhibition Schedule
    • Training
    • Employment Opportunities
    • Ethics Policies
  • Documents
    • Data Sheets
    • End User Statement Form
    • Technical Articles
    • Warranty
    • Radioactive Material License
    • Terms & Conditions
  • Contact
    • Headquarters
    • Sales Contact Form
    • Support Contact Form
    • Feedback Form
Automatic Systems Manual Systems Multi-Detector Systems Help Me Choose

Accessories

Planchets

DescriptionPart Number
1/8 in. Planchet2 x 1/8 in., Stainless Steel, Set of 100 700-0007
1/4 in. Planchet2 x 1/4 in., Stainless Steel, Set of 100 700-0008
5/16 in. Planchet2 x 5/16 in., Stainless Steel, Set of 100 700-0009

Sample Carriers

DescriptionPart Number
Sample CarrierStandard Carrier Set 1-50 + QC + Routine 120-0033
Sample CarrierCarrier Any Sequence, Set of 50 120-0034

Sample Carrier Inserts

DescriptionPart Number
1/8 in. Insert1/8 in. Carrier Insert, Set of 50 140-0305-01
1/4 in. Insert1/4 in. Carrier Insert, Set of 50 140-0305-02
5/16 in. Insert5/16 in. Carrier Insert, Set of 50 140-0305-03

Guard Detector Option for Dual-Phosphor Detector Systems

Protean Instrument's systems with dual phosphor detectors, ASC-950-DP and MPC-900-DP, now include a cosmic guard detector option. A guard detector should be used whenever the requirement for lower beta background exists. A guard detector lowers beta background by helping to eliminate the interference in a beta measurement caused by cosmic events or background counts. Cosmic background counts are eliminated using electronic rejection in conjunction with a cosmic (guard) detector. The guard detector is of similar construction as the primary sample detector and is mounted such that it will intercept any cosmic radiation seen by the sample detector. Any event detected in the sample detector which is coincident with an event detected in the guard detector is rejected.

The end result of the optional guard detector is a reduced beta background which increases the performance of the instrument dramatically. A system utilizing a guard detector typically reaches the required MDA in approximately half the counting time of a system without a guard detector.

 

Software

 

ImageProductDescription
vfc-logo Vista FC Instrument control software for health physics applications
Vista 2000 Logo Vista 2000 Instrument control software for radiochemistry applications
DUO DUO
Software to import and export data between a PC and an instrument

Detectors

Gas Flow

Protean Instrument uses two types of gas-flow proportional detectors. Both models are designed and manufactured by Protean. These detectors require a steady supply of industrial grade P-10 (10% methane and 90% argon) counting gas. Flow rates vary based on the detector, ranging between 60–150 cc/min at 10 psi pressure.

Pancake Detector

The pancake design is used in the WPC-1050, WPC-1150-Series, and the MDS-Series. It is an ultra-thin window design and must be operated with a window in place.

pancake

 

Hemispherical Detector

The hemispherical detector is designed for windowless operation, but can also be operated with an ultra-thin window in place. The Protean windowless detector is designed for easy cleaning, with a smooth plated interior surface that minimizes trapping points. The detector anode wire can be easily cleaned or replaced by the user without disassembling the shield. The hemispherical detector is used in the IPC-650-Series, MPC-900-GFW, MPC-900-GFL, and the MPC-1000-Series.

hemiside

Gasless

Protean utilizes a dual phosphor scintillator type detector for applications where portability or gas-free operations are desired.  The dual phosphor detector gets its name from the use of ZnS(Ag) that is adhered to a thin disk of plastic scintillator. These detectors are always supplied with an 80 µg/cm2 aluminum window. This assembly is coupled to a photomultiplier tube and then encased in a light tight enclosure. All that is required to acquire counts is applied voltage. No gas is required.

The dual phosphor detectors provide excellent alpha-beta efficiency, albeit not at the same performance level of the gas flow detectors. Their portable, gas-free use, however, has made them a popular detector type for performing alpha/beta type measurements. These detectors are currently employed in Protean's ASC-950-DP and MPC-900-DP.

 54G8820

Instrument Comparison Chart

Automatic Systems

Image ASC 950 DP G WPC 1050 WPC 1150 Series old WPC 1150 Series old
Model ASC-950-DP WPC-1050 WPC-1150-GFW-3.5 WPC-1150-GFW-5
Detector Type Dual Phosphor Gas Flow Proportional Gas Flow Proportional Gas Flow Proportional
Counter Type Gross Bkg Low Bkg Low Bkg Low Bkg
Sample Size 2 in. (5.1 cm) 2 in. (5.1 cm) 3.5 in. (8.9 cm) or custom 5 in. (12.7 cm) or custom
Sample Capacity 50
(100 optional)
50
(100 optional)
50 50
Windowless Capable No No No No
Applications  Health Physics,
Environmental
Health Physics,
Radiochemistry,
Environmental
Health Physics,
Environmental
Health Physics,
Environmental

Manual Systems

Image mpc-900 mpc-900 MPC 1000
Model MPC‑900‑DP MPC-900-GF MPC-1000-GF
Detector Type Dual Phosphor Gas Flow Proportional Gas Flow Proportional
Counter Type Gross Bkg Gross Bkg Low Bkg
Sample Size 2 in. (5.1 cm) 2 in. (5.1 cm) 2 in. (5.1 cm)
Windowless Capable No Yes Yes
Applications Health Physics Radiochemistry,
Environmental
Radiochemistry,
Environmental

Multi-Detector Systems

Image MPC9604
Model MPC-9604
Detector Type Gas Flow Proportional
Counter Type Low Bkg
Sample Size 2 in. (5.1 cm)
Sample Capacity 4
Windowless Capable No
Applications Radiochemistry,
Environmental

Featured Products

WPC-1050

WPC-1050

Automatic Sample Changer
Gas Flow Proportional Detector

Learn More
ASC-950-DP

ASC-950-DP

Automatic Sample Changer
Dual Phosphor Detector
Guard Capable

Learn More
MPC-900-DP

MPC-900-DP

Manual Sample Changer
Dual Phosphor Detector

Learn More
MPC-9604

MPC-9604

Manual Sample Changer
Four Gas Flow Proportional Detectors

Learn More
MPC-1000

MPC-1000

Manual Sample Changer
Gas Flow Proportional Detector

Learn More

New Guard Detector Option

New guard detector option for ASC-950-DP and MPC-900-DP dual phosphor systems.

Learn More