The MPC-900-GFW and MPC-900-GFL are convenient and versatile benchtop counters equipped with hemispherical gas-flow proportional type detectors that support easy portability. These sample counters are ideal for standard health physics applications such as smears and air filters. They can also be used for radiochemistry applications when alpha only counting is of interest. The MPC-900-GFL uses a windowless gas-flow proportional detector that delivers higher efficiencies for projects involving alpha emitters and higher activity low-energy beta emitters. Each counter has the ability to program routines and QC charts on a PC running the included DUO Express software, then transfer the routines to the instrument using a direct-connect PIC Link cable.
MPC-900-GFW Part Number: 105-900-W
MPC-900-GFL Part Number: 105-900-WL
All specifications are subject to change without notice.
| Sample Detector | 2.25 in. (5.7 cm) diameter, hemispherical style gas flow proportional |
|---|---|
| Window | MPC-900-GFW: Aluminized, 80 µg/cm2 MPC-900-GFL: Windowless |
| Counting Gas | P-10, 60 cc/min. at 10 psi |
| Gas-PRO™ | Fail-safe P-10 monitoring system senses breaches in gas flow |
| Shielding | Optional lead ring (see Options & Accessories tab) |
| Sample Size | 2 in. (5.1 cm) diameter planchets, 1/8, 1/4, 5/16 in. (3.2, 6.3, 7.9 mm) deep |
| Count Modes | Alpha only, Alpha/Beta simultaneously, Alpha then Beta |
| Interface | Touch screen |
| Data Export | USB PIC Link, USB Flash Drive |
| Power | 110 - 240 Vac, 50 - 60 Hz input |
| Environment | |
| Size (H x W x D) | 20.25 x 9 x 16 in. (51.4 x 22.9 x 40.6 cm) |
| Weight | 40 lb (18.1 kg) |
Typical Background
| Alpha | Beta | |
|---|---|---|
| Without Lead | 0.05 cpm (warranted < 0.1 cpm) |
40 cpm (warranted < 55 cpm) |
| With Lead | 0.05 cpm (warranted < 0.1 cpm) |
30 cpm (warranted < 45 cpm) |
Typical Efficiency - MPC-900-GFW (windowed)
| Source | Top | 1/8 in. (3.2 mm) Bottom | 1/4 in. (6.3 mm) Bottom | 5/16 in. (7.9 mm) Bottom |
|---|---|---|---|---|
| 239Pu | 40% | 32% | 26% | 24% |
| 90Sr/90Y | 55% | 48% | 40% | 37% |
| 99Tc | 47% | 37% | 30% | 27% |
Typical Efficiency - MPC-900-GFL (windowless)
| Source | Top | 1/8 in. (3.2 mm) Bottom | 1/4 in. (6.3 mm) Bottom | 5/16 in. (7.9 mm) Bottom |
|---|---|---|---|---|
| 239Pu | 47% | 47% | 47% | 47% |
| 90Sr/90Y | 60% | 62% | 62% | 62% |
| 99Tc | 58% | 58% | 58% | 58% |
Compatible Protean Application Software Packages
| Description | Part Number |
|---|---|
| Lead Ring, 50 lb (22.7 kg) | 120-0010-GF |
| Centering Ring | 140-0045 |
| AL Carrier, 1/8 in., 1/4 in., or 5/16 in. depth | 140-0278 |
Planchet, 2 in. x 1/8 in., set of 100 |
700-0007 |
Planchet, 2 in. x 1/4 in., set of 100 |
700-0008 |
Planchet, 2 in. x 5/16 in., set of 100 |
700-0009 |
| Description | Part Number |
|---|---|
| Low Voltage Power Supply, 12 V | 110-0013 |
| 2.25 in. Windowless Hemispherical Detector Assembly | 110-1001 |
| 2.25 in. Windowed Hemispherical Detector Assembly | 110-1010 |
| CPU | 110-1044-1 |
| High Voltage Power Supply | 110-1047-1 |
| Powered Patton Box RS485 Converter | 110-1069 |
| Gas Flow Sensor Assembly | 110-1074 |
| Gas Dual Amp | 110-1077 |
| PIC Link Cable | 11M-0014 |
| 2.25 in. Anode Assembly | 120-0006 |
| Windowless Seal Kit | 120-0007 |
| 2.25 in. Window | 120-0008 |
| Gas Regulator Assembly | 120-0025 |
| Window Gasket, Set of 3 | 120-0037 |
| Windowless Gasket, Set of 3 | 120-0038 |
| Touch Screen | 245-0003 |
| RS232 Cable, 15 ft. | 6XXX-0008 |
© 2026 Protean Instrument